A 100 km Three-Phase 50 Hz transposed transmission line is çomposed of bundle of three ACSR, 1,431,000 çmil, 47/7 Bobolink conductors as shown in Figure 2 (a). The Three- Phases (bundled Conductors) have flat horizontal spacing of 11 meters as shown in the Eigure 2(a). The conductors have a diameter of 3.8 cm and a GMR of 1.5 cm. The Line is going to be replaced with a six conductor bundle of ACSR, 477,000 çmil, 26/7 Hawk conductors. The conductors have a diameter of 2.5 cm and a GMR of 0.9 cm. The new Jine will have a horisontal phase spacing of 14 meters as it is going to be operated at higher Veltage rating, The new line is shown in Figure 2 (b). The spacing between the bundles in Figure 2 (a) and (b) is 45 cm. Determine. a) The capacitance for each case and the percentage change in capacitance b) The inductive reactance for each line and the percentage change. c) The inductance for each case and the percentage change in inductance 11 m (a) 11 m OLD TRANSMISSION LİNE 0.45 m 0.45 m 0.45 m 0.45 m 0.45 m 0.45 m 14 m 14 m (b) NEW TRANSMISSION LINE

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question

please help me step by step solve thank you

A 100 km Three-Phase 50 Hz transposed transmissioa line is composed of bundle of three
ACSR, 1,431,000 çmil, 47/7 Bobolink conductors as shown in Eigure 2 (a). The Three-
Rhases (bundled Conductors) have flat horizontal spacing of 11 meters as shown in the
Eigure 2(a). The conductors have a diameter of 3.8 cm and a GMR of 1.5 cm. The Line is
going to be replaced with a six conductor bundle of ACSR, 477,000 çmil, 26/7 Hawk
conductors. The conductors have a diameter of 2.5 cm and a GMR of 0.9 cm. The new line
will have a horisontal phase spacing of 14 meters as it is going to be operated at higher
Voltage rating, The new line is shown in Figure 2 (b). The spacing between the bundles in
Eigure 2 (a) and (b) is 45 cm. Determine.
a) The capacitance for each case and the percentage change in çapacitance
b) The inductive reactance for each line and the percentage change.
c) Jhe inductance for each case and the percentage change in inductance
11 m
(a)
11 m
OLD TRANSMISSION LİNE
0.45 m
0.45 m
0.45 m
0.45 m
0.45 m
0.45 m
14 m
14 m
(b)
NEW TRANSMISSION LINE
Transcribed Image Text:A 100 km Three-Phase 50 Hz transposed transmissioa line is composed of bundle of three ACSR, 1,431,000 çmil, 47/7 Bobolink conductors as shown in Eigure 2 (a). The Three- Rhases (bundled Conductors) have flat horizontal spacing of 11 meters as shown in the Eigure 2(a). The conductors have a diameter of 3.8 cm and a GMR of 1.5 cm. The Line is going to be replaced with a six conductor bundle of ACSR, 477,000 çmil, 26/7 Hawk conductors. The conductors have a diameter of 2.5 cm and a GMR of 0.9 cm. The new line will have a horisontal phase spacing of 14 meters as it is going to be operated at higher Voltage rating, The new line is shown in Figure 2 (b). The spacing between the bundles in Eigure 2 (a) and (b) is 45 cm. Determine. a) The capacitance for each case and the percentage change in çapacitance b) The inductive reactance for each line and the percentage change. c) Jhe inductance for each case and the percentage change in inductance 11 m (a) 11 m OLD TRANSMISSION LİNE 0.45 m 0.45 m 0.45 m 0.45 m 0.45 m 0.45 m 14 m 14 m (b) NEW TRANSMISSION LINE
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Thermistors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,