99m 27. A shielded vial with a 1-mm thick lead shield contains hTe. If A. 11.8 mR/hr B. 23.5 mR/hr the unshielded sample yielded an exposure rate of 188 mR/hr, what will the exposure rate be from the shielded vial? (The lead HVL for Tc is 0.25 mm.) C. 47 mR/hr D. 94 mR/hr
Q: 2. If the recommended effective dose in the lab is 500 µSv per week, find the time has been expended…
A: Given that:- Q=500 μSv=500×10-6 SvR=100 nSv/hr=100×10-9 Sv/hrt=?
Q: 9. The density of bcc iron is 7.9 × 10' kg/m' and the atomic weight is 56. Calculate the size of the…
A: Given that:-Density, d=7.9×103 kg/m3Atomic weight, M=56The unit cell is BCCWe know that,d=Z×Ma3NA…
Q: A Co-60 source gives a gamma dose rate of 120 μSv/h at 2.2 m away. At what distance (in meter) will…
A:
Q: The dosage of technetium-99m for a lung scan is 20. µCi /kg of body mass. How many millicuries of…
A: Given the dosage of technetium-99m for a lung scan is 20. µCi /kg of body mass. - How many…
Q: d the minimum sample size n needed to estimate μ for the given values of c, σ, and E. c=0.90,…
A: c=0.90, σ=8.9, and E=2 Find:- Find the minimum sample size n needed to estimate μ, Assume that a…
Q: Using the new instrument on the first day the technicians got a value of 33 ppb. Are the technicians…
A:
Q: Referring to this figure, calculate Av if rd = 19 ko.V = 6.42V GSQ 12 V 2 kn HO V. 1 μF Zo 10 Mn…
A:
Q: An ac source with an amplitude of 600 V drives an L-R-C series circuit. The voltage vC acrOss the…
A:
Q: if a record sample has rate of 44100Hz, how many samples are required to capture 0.25s?
A:
Q: . A Geiger counter measures background radiation and records 950 counts in 10 minutes. Then the…
A:
Q: the source only 3. Suppose in this experiment, the penetration depth in lead is 9.4 mm (which is not…
A: Radiation when travelling through material experiences attenuation. In lead also the radiation is…
Q: From the average of these values, determine the maximum number of hours you could work with this…
A: Given permissible annual dose is D=2.4mSv=2.4x10-3Sv And number of working days in a year is…
Q: A 1-curie source is located just behind a shielding. If the shield has an HVL of 8 cm, how thick…
A: Disclaimer: “Since you have asked multiple question, we will solve the first question for you. If…
Q: A 729 range meter is having an accuracy of ± 1.45% of FSD. Calculate the %error for a measurement of…
A: Here we use the formula for accuracy and error to calculate the required quantites.
Q: What is 28 mg coverted into kilograms? I put 2.8 e-5 and it was incorrect on Webassign.
A: 28 mg can be converted as follows.
Q: 3. Find the percent error of the experimental value we found for the density of the unknown sample…
A: Error in measurements is because of several reasons now consider only the instrumental errors so if…
Q: What is the exposure rate at 30 cm from a vial containing 20 mCi (740 MBq) of 131I?
A:
Q: A radiographic technique calls for 46 kVp and 28 mAs which results in an exposure of 278 µGy. What…
A: The primary exposure technique factors the radiographer selects on the control panel are…
Q: 29. A shielded vial with a 0.1-mm thick lead shield contains 1. This shielded sample yields an…
A: 29 Given: The thickness of the lead is t=0.1 mm. The exposure rate with a shield at a distance of 3…
Q: Operating console controls are set at 200 mA with an exposure time of s. What is the…
A:
Q: “Diffusion” sounds slow—and over everyday dis-tances it is—but on the scale of a cell it is very…
A: The average instantaneous velocity is given as:v=kTmwhere,k is 1.38×10-16 g.cm2/K.s2T is in Kelvinm…
Q: A beam of 5.0 MeV alpha particles (q-2e) has a cross-sectional area of 1.50 cm2. It is incident on…
A:
Q: the V•O2max of people tends to declineafter age 30 by about 9% per decade for sedentary…
A: Given: The volume of oxygen of 30 year old is 3.1 L/min In sedentary individuals, decline is…
Q: 5. A small calibrated dosimeter records an exposure of 200 R when embedded in an equilibrium…
A: Given: Dosimeter records an exposure of 200 R HVL = 2.0 mm eu To find the dose to the bone Formula…
Q: A radioactive source is producing 1.50 MeV gamma rays. If two detectors are placed 4.00 m and 7.00 m…
A: Distance of two detecters from the source…
Q: A worker will need to conduct a repair to a pipe containing radioactive waste. The pipe is 10 m…
A: Part (a): Given that the distance of the worker from the radiation pipe is 50 cm, the radiation dose…
Q: 3. The amount of Dr. Pepper dispensed by a soda machine is normally distributed with a mean of 63.0…
A:
Q: Activity 1: Unit Conversion 1. 1233457 Tb to kb
A: A data is a collection of information. And the kilobyte and the terabyte are the two units of the…
Q: ' A GM counter records 16.000 Counts per minute. while the true counting rate is 17.400 counts per…
A: Given: Counts per minute m=16.000. True count per N=17.400. Introduction: In GM tube after every…
Q: given 4hrs of 80dBA exposure ,2hrs of90 dBA exposure and 2hrs of 85 dBA exposure,what is the % dose?…
A:
Q: 3.3 A cylindrical air wall chamber of radius 0.5 cm with a central electrode of radius 0.05 cm is…
A: Solution: Given that, ab=0.50.05=10 Exposure rate=240 R/min=1 R/sec Here, Key=1.19
Q: 250 mA and .2 sec creates a good radiograph of a lateral thoracic spine with appropriate exposure to…
A:
Q: Based on the linear, non-threshold dose-response model, the risk factors for excess cancer incidence…
A: Answer in the next step.....
Q: 18.6 An is 5x10 3 behind shield block with ray orifice of source m a an chamber 0.1 m from the…
A:
Q: During a laboratory experiment, the average rate of radioactive particles passing through a counter…
A: We use Poisson distribution to find the probability. Given: λ = 5, t = 1 λt = 5, x = 6
Q: The potential energy of the reactants is represented by the letter The potential energy of the…
A: we have to designate which of the letter denotes the products and reactants
Q: What is the exposure rate at 30 cm from a vial containing 20 mCi (740 MBq) of 15'1?
A: 20 mCi Point source, distance values are d1 =0.30 m and d2 = 1 meter , I 2 = .22 Mr/ hr/ mci * 20…
Q: At 3 ft from a source, the dose rate is 25 mrem/hr. How far away from the source should somebody so…
A: According to guidelines we need to solve only first question kindly repost other questions in the…
Q: 1. You are required to perform to perform constancy or precision testing to assure the…
A: The fill ups can be written as,
Q: the minimum sample size n needed to estimate μ for the given values of c, σ, and E.
A: σ= 7.4 c= 0.90and E = 2 Find:- Find the minimum sample size n needed to estimate
Q: If the gamma-ray dose rate is 50 mSv hr-1 at a distance of 1.0 m from a source, what is the dose…
A: Given data, Dost rate is I1=50 mSvhr-1 when distance d1=1 m. Distance d2=10 m.
Q: technetium half life is 4.8 hours. If a patient receicves a dose with an activity of 35.9 mCi of…
A: Half life of technetium (t1/2) = 4.8 hours Initial activity (Ao) = 35.9 mCi
Q: A generator is calibrated to contain 500 mCi of "Mo at noon on Friday, July 22 at 8 am. The…
A: Technetium-99m (Tc-99m) is derived from the decay of Molybdenum-99 The half-life of 99Mo is…
Q: A. 1.8 Sv 43. A patient received a full-body electron dose of 240 mGy, a neutron dose (1 MeV) of 43…
A: Effective dose is used to assess the potential for long-term effects that might occur in the future.…
Step by step
Solved in 2 steps with 2 images