9. Which temperature measurement device is mostly used in industry? A) Gas thermometry B) Thermocouples C) Bimetallic thermometers D) Thermal Camera

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
100%
8. During the drive, you can take fresh air using the conditioning system available in
the automobile. However, you should slightly open (about 1 cm) your window for the
exhausting some air, according to the mass balance principle. If you open your
window completely, the intake of fresh air and exhaust of polluted air will deteriorate.
Based on this information, what do you think about pressure balance?
A) Pautomobile Poutside
B) Pautomobile = Poutside
C) Pautomobile > Poutside
D) Pautomobile SPoutside
9. Which temperature measurement device is mostly used in industry?
A) Gas thermometry
B) Thermocouples
C) Bimetallic thermometers
D) Thermal Camera
10. Which measuring instrument should be preferred to convert qualitative measurement
with thermochromic liquid crystals to quantitative data.
A) Resistance Temperature Detector
B) Thermocouples
C) Bimetallic thermometers
D) Thermal Camera
11. Which of the temperature measurement technique is used for visual warning of
certain temperature limits?
A) Thermocouples
B) Thermal Camera
C) Resistance Temperature Detector
D) Infrared Thermometry
12. What is the use of Wheatstone bridge in a force measurement device? Please also give
the name of measuring device for the purpose.
A) Fiber Optic load cell
B) Electronic load cell
C) Strain Gauge Load Cells
D) Linear Displacement Sensors
13. Which force measurement device would you prefer to use if your consideration is
force changing occurs dynamically ?
A) Piezoelectric Mass Sensor
B) Shear Beam load cell
C) Bending Beam load cell
D) Pneumatic load cell
13. It is possible to use a piezoelectric mass sensor for measuring the weight of a truck. (5P)
A) True B) False
14. The diameter of a wire is measured using a micrometer. The uncertainty in the
measurement is +0.01 mm. The diameter D is 0.27 mm. What is the percent uncertainty in
the AREA of the wire?
A) 10 % B) 1 % cell C) 5. 7% D) 7.5
Transcribed Image Text:8. During the drive, you can take fresh air using the conditioning system available in the automobile. However, you should slightly open (about 1 cm) your window for the exhausting some air, according to the mass balance principle. If you open your window completely, the intake of fresh air and exhaust of polluted air will deteriorate. Based on this information, what do you think about pressure balance? A) Pautomobile Poutside B) Pautomobile = Poutside C) Pautomobile > Poutside D) Pautomobile SPoutside 9. Which temperature measurement device is mostly used in industry? A) Gas thermometry B) Thermocouples C) Bimetallic thermometers D) Thermal Camera 10. Which measuring instrument should be preferred to convert qualitative measurement with thermochromic liquid crystals to quantitative data. A) Resistance Temperature Detector B) Thermocouples C) Bimetallic thermometers D) Thermal Camera 11. Which of the temperature measurement technique is used for visual warning of certain temperature limits? A) Thermocouples B) Thermal Camera C) Resistance Temperature Detector D) Infrared Thermometry 12. What is the use of Wheatstone bridge in a force measurement device? Please also give the name of measuring device for the purpose. A) Fiber Optic load cell B) Electronic load cell C) Strain Gauge Load Cells D) Linear Displacement Sensors 13. Which force measurement device would you prefer to use if your consideration is force changing occurs dynamically ? A) Piezoelectric Mass Sensor B) Shear Beam load cell C) Bending Beam load cell D) Pneumatic load cell 13. It is possible to use a piezoelectric mass sensor for measuring the weight of a truck. (5P) A) True B) False 14. The diameter of a wire is measured using a micrometer. The uncertainty in the measurement is +0.01 mm. The diameter D is 0.27 mm. What is the percent uncertainty in the AREA of the wire? A) 10 % B) 1 % cell C) 5. 7% D) 7.5
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Basic Thermodynamic Processes
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY