8.a. Four electricians are discussing transformer installations. Electrician A says that there's no size requirement for the door sill of a transformer vault as long as the sill contains the oil from the largest transformer. Electrician B says that the AHJ can require a fire rating of three hours for vault doors on an exterior wall. Electrician C says that the minimum height requirement for the sill is 3″. Electrician D says that a three-hour fire-rated door is even required for a vault with an automatic sprinkler system. Which of the following statements is correct? A. Electrician A is correct. B. Electrician C is correct. C. Electrician B is correct. D. Electrician D is correct. 8.b. Four electricians are discussing hazardous locations. Electrician A says that hazardous-location classifications are determined by the presence of gases, dust, or ignitable fibers. Electrician B says that Division 2 conditions would create a fire or explosion under normal circumstances. Electrician C says that hazardous-location classifications are determined by the presence of gases, dust, available water, or ignitable fibers. Electrician D says that the presence of hazardous substances doesn't limit a selection of wiring. Which of the following statements is correct? A. Electrician D is correct. B. Electrician C is correct. C. Electrician B is correct. D. Electrician A is correct.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
100%

8.a. Four electricians are discussing transformer installations. Electrician A says that there's no size
requirement for the door sill of a transformer vault as long as the sill contains the oil from the largest
transformer. Electrician B says that the AHJ can require a fire rating of three hours for vault doors on an
exterior wall. Electrician C says that the minimum height requirement for the sill is 3″. Electrician D says
that a three-hour fire-rated door is even required for a vault with an automatic sprinkler system. Which of
the following statements is correct?
A. Electrician A is correct.
B. Electrician C is correct.
C. Electrician B is correct.
D. Electrician D is correct.

8.b. Four electricians are discussing hazardous locations. Electrician A says that hazardous-location
classifications are determined by the presence of gases, dust, or ignitable fibers. Electrician B says that
Division 2 conditions would create a fire or explosion under normal circumstances. Electrician C says that
hazardous-location classifications are determined by the presence of gases, dust, available water, or
ignitable fibers. Electrician D says that the presence of hazardous substances doesn't limit a selection of
wiring. Which of the following statements is correct?
A. Electrician D is correct.
B. Electrician C is correct.
C. Electrician B is correct.
D. Electrician A is correct.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Hydrostatic forces
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning