- 500 A 30 Q 75 2 75 2 F2 15A T la- 200 A Setting of the Distance Relay = 150 0 Figure Q3(c) (c) Figure Q3(c) shows distance protection of a section of power system. The zone setting at A and B is 150 ohms. (i) Produce the impedance seen by the relay at A for a fault at F1. (ii) Predict whether the relay at A will operate or not, before the circuit breaker at B is tripped. (iii) Plan your answer, for the relay at B trip or not for a fault at F1 before the circuit breaker at A is tripped. (iv) If the circuit breaker C; fails for a fault at F2, make decision about the clearance of fault by the relays at A and B: (v) Comment your views for the clearance of fault at F2.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Solve all parts.

- 500 A
30 Q
75 2
75 2
F2
15A
T la- 200 A
Setting of the Distance Relay = 150 0
Figure Q3(c)
(c)
Figure Q3(c) shows distance protection of a section of power system. The
zone setting at A and B is 150 ohms.
(i) Produce the impedance seen by the relay at A for a fault at F1.
(ii) Predict whether the relay at A will operate or not, before the circuit
breaker at B is tripped.
(iii) Plan your answer, for the relay at B trip or not for a fault at F1 before
the circuit breaker at A is tripped.
(iv) If the circuit breaker C; fails for a fault at F2, make decision about the
clearance of fault by the relays at A and B:
(v) Comment your views for the clearance of fault at F2.
Transcribed Image Text:- 500 A 30 Q 75 2 75 2 F2 15A T la- 200 A Setting of the Distance Relay = 150 0 Figure Q3(c) (c) Figure Q3(c) shows distance protection of a section of power system. The zone setting at A and B is 150 ohms. (i) Produce the impedance seen by the relay at A for a fault at F1. (ii) Predict whether the relay at A will operate or not, before the circuit breaker at B is tripped. (iii) Plan your answer, for the relay at B trip or not for a fault at F1 before the circuit breaker at A is tripped. (iv) If the circuit breaker C; fails for a fault at F2, make decision about the clearance of fault by the relays at A and B: (v) Comment your views for the clearance of fault at F2.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Types of Semiconductor Material and Its Energy Band Analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,