5. An analyst at Procter & Gamble quality control department received a sample of toothpaste to determine the %fluoride. The analyst prepared a series of fluoride calibration standards and a total ionic strength adjusting buffer (TISAB) to standardize the fluoride electrode. The results of the potential measurements of the calibration standards are depicted on the figure. The analyst dissolved 0.2364 g of the toothpaste in 100 ml of DI water containing the TISAB. Then, measured the potential of the toothpaste solution to be-170 mv. -100 -200 10 lewe d - Estimate the linear concentration range of this fluoride selective electrode. Peal chang, V

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
50
5. An analyst at Procter & Gamble quality control department
received a sample of toothpaste to determine the %fluoride. The
analyst prepared a series of fluoride calibration standards and a
total ionic strength adjusting buffer (TISAB) to standardize the
fluoride electrode. The results of the potential measurements of
the calibration standards are depicted on the figure. The analyst
dissolved 0.2364 g of the toothpaste in 100 ml of DI water
containing the TISAB. Then, measured the potential of the
toothpaste solution to be -170 mv.
-100
-150
-200
-250
300
10
Lewer deteton
Uer detten
- Estimate the linear concentration range of this fluoride selective electrode.
i- Calculate the concentration of fluoride in the toothpaste solution.
li- Calculate the mass of fluoride in the toothpaste sample.
iv- Calculate the %F- in this toothpaste.
y-63.1x - 401.2
Potential change, mV
Transcribed Image Text:50 5. An analyst at Procter & Gamble quality control department received a sample of toothpaste to determine the %fluoride. The analyst prepared a series of fluoride calibration standards and a total ionic strength adjusting buffer (TISAB) to standardize the fluoride electrode. The results of the potential measurements of the calibration standards are depicted on the figure. The analyst dissolved 0.2364 g of the toothpaste in 100 ml of DI water containing the TISAB. Then, measured the potential of the toothpaste solution to be -170 mv. -100 -150 -200 -250 300 10 Lewer deteton Uer detten - Estimate the linear concentration range of this fluoride selective electrode. i- Calculate the concentration of fluoride in the toothpaste solution. li- Calculate the mass of fluoride in the toothpaste sample. iv- Calculate the %F- in this toothpaste. y-63.1x - 401.2 Potential change, mV
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Knowledge Booster
Electrochemical Cells
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY