5) In the catalog of a pressure measuring transducer, the manufacturer has provided the following information. If a 500 cm H2O pressure is to be measured using this transducer and the ambient temperature changes between 18 and 25 °C during the measurement, it is desirable to determine the degree of uncertainty caused by each of the sources of errors that may affect the measurement results. Affect? Operation Input range Excitation 0-1000 cm H2O ±15 V DC Output range 0-5 V Performance +0.5% FSO Linearity error Hysteresis error Sensitivity error Thermal sensitivity error Less than +0.15% FSO +0.25% of reading +0.02%/C of reading Thermal zero drift +0.02%/C FSO Temperature range 0-50 °C FSO, full-scale operating range. Table 4: Specifications provided in the transducer catalog for pressure measurement

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
5) In the catalog of a pressure measuring transducer, the manufacturer has provided
the following information. If a 500 cm H20 pressure is to be measured using this
transducer and the ambient temperature changes between 18 and 25 °C during the
measurement, it is desirable to determine the degree of uncertainty caused by each
of the sources of errors that may affect the measurement results. Affect?
Operation
Input range
0-1000 cm H20
Excitation
±15 V DC
Output range
0-5 V
Performance
Linearity error
Hysteresis error
Sensitivity error
Thermal sensitivity error
Thermal zero drift
±0.5% FSO
Less than +0.15% FSO
+0.25% of reading
+0.02%°C of reading
+0.02%/C FSO
Temperature range
0-50 °C
FSO, full-scale operating range.
Table 4: Specifications provided in the transducer catalog for pressure measurement
Transcribed Image Text:5) In the catalog of a pressure measuring transducer, the manufacturer has provided the following information. If a 500 cm H20 pressure is to be measured using this transducer and the ambient temperature changes between 18 and 25 °C during the measurement, it is desirable to determine the degree of uncertainty caused by each of the sources of errors that may affect the measurement results. Affect? Operation Input range 0-1000 cm H20 Excitation ±15 V DC Output range 0-5 V Performance Linearity error Hysteresis error Sensitivity error Thermal sensitivity error Thermal zero drift ±0.5% FSO Less than +0.15% FSO +0.25% of reading +0.02%°C of reading +0.02%/C FSO Temperature range 0-50 °C FSO, full-scale operating range. Table 4: Specifications provided in the transducer catalog for pressure measurement
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
Protection System for Machines
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,