4. When a generator has terminal a open and the other two terminals are connected to each other with a short circuit from the connection to ground, typical values for the symmetrical components of current in phase a are Ia (1) = 600/-90°, Ia(2) - 250/90°and Ia (0)= 350/90°A. Find the current into the ground a. 1700 A b. 1920 A c. j1050 A d. ji180 A

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

l10

answer 4 5 6

4. When a generator has terminal a open and the other two
terminals are connected to each other with a short circuit
from the connection to ground, typical values for the
symmetrical components of current in phase a are Ia (1) =
600/-90°, Ia(2) - 250/90°and Ia (0)= 350/90°A. Find the
current into the ground
a. 1700 A
b. 1920 A
c. j1050 A
d. j1180 A
Transcribed Image Text:4. When a generator has terminal a open and the other two terminals are connected to each other with a short circuit from the connection to ground, typical values for the symmetrical components of current in phase a are Ia (1) = 600/-90°, Ia(2) - 250/90°and Ia (0)= 350/90°A. Find the current into the ground a. 1700 A b. 1920 A c. j1050 A d. j1180 A
5. A generator is rated 500 MVA, 22 kv. The positive, negative
and zero sequence components of the generator are 0.20,
0.20 and 0.05 per unit respectively. What is the ratio of
the fault current for a single line to ground fault to the
fault current for a three-phase fault?
а. 1.50
b. 1.42
с. 1.33
d. 1.25
6. A 30 MVA generator with 15% reactance is connected to a bus
bar. A 25 MVA transformer with 10% reactance is also
connected through a 10% bus bar reactor to the same bus
bar. Both of these reactance is based on 25 MVA. If a
feeder taken out from the bus bars through a circuit
breaker develops a three-phase fault, what should be the
appropriate rating of the circuit breaker?
a. 923 MVA
b. 325 MVA
c. 675 MVA
d. 500 MVA
Transcribed Image Text:5. A generator is rated 500 MVA, 22 kv. The positive, negative and zero sequence components of the generator are 0.20, 0.20 and 0.05 per unit respectively. What is the ratio of the fault current for a single line to ground fault to the fault current for a three-phase fault? а. 1.50 b. 1.42 с. 1.33 d. 1.25 6. A 30 MVA generator with 15% reactance is connected to a bus bar. A 25 MVA transformer with 10% reactance is also connected through a 10% bus bar reactor to the same bus bar. Both of these reactance is based on 25 MVA. If a feeder taken out from the bus bars through a circuit breaker develops a three-phase fault, what should be the appropriate rating of the circuit breaker? a. 923 MVA b. 325 MVA c. 675 MVA d. 500 MVA
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Current division Method
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,