30.13 A stent is used to "prop up" a clogged artery to allow blood to pass through it. But stents can also be loaded with drugs to facilitate the timed release of the drug into the body, especially if the drug is not very soluble in body fluids. Consider the very simple stent design as illustrated below. The pole of the stent, which is 0.2 cm in diameter and 1.0 cm in length, is coated with the anticancer drug Taxol. The thickness of the coating is 0.01 cm and 5.0 mg total Taxol is loaded. Blood flows through the 1.0 cm diameter cylindrical blood vessel at a volumetric flow rate of 10.0 cm /s. Taxol is not very soluble in aqueous environments; the maximum solubility of Taxol in blood is 2.5 × 10¬4 mg/cm³. The viscosity of blood is 0.040 g/cm - s and its density is 1.05 g/cm³. Blood is a complex fluid but you may assume that its average molecular weight is close to that of liquid water. The molecular diffusion coefficient of Taxol in fluid blood is DAB = 1.0 × 10-6 cm²/s.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
30.13 A stent is used to "prop up" a clogged artery to allow
blood to pass through it. But stents can also be loaded with drugs
to facilitate the timed release of the drug into the body, especially
if the drug is not very soluble in body fluids. Consider the very
simple stent design as illustrated below. The pole of the stent,
which is 0.2 cm in diameter and 1.0 cm in length, is coated with
the anticancer drug Taxol. The thickness of the coating is 0.01 cm
and 5.0 mg total Taxol is loaded. Blood flows through the 1.0 cm
diameter cylindrical blood vessel at a volumetric flow rate of
10.0 cm /s. Taxol is not very soluble in aqueous environments;
the maximum solubility of Taxol in blood is 2.5 × 10¬4 mg/cm³.
The viscosity of blood is 0.040 g/cm - s and its density is
1.05 g/cm³. Blood is a complex fluid but you may assume
that its average molecular weight is close to that of liquid water.
The molecular diffusion coefficient of Taxol in fluid blood is
DAB = 1.0 × 10-6 cm²/s.
Transcribed Image Text:30.13 A stent is used to "prop up" a clogged artery to allow blood to pass through it. But stents can also be loaded with drugs to facilitate the timed release of the drug into the body, especially if the drug is not very soluble in body fluids. Consider the very simple stent design as illustrated below. The pole of the stent, which is 0.2 cm in diameter and 1.0 cm in length, is coated with the anticancer drug Taxol. The thickness of the coating is 0.01 cm and 5.0 mg total Taxol is loaded. Blood flows through the 1.0 cm diameter cylindrical blood vessel at a volumetric flow rate of 10.0 cm /s. Taxol is not very soluble in aqueous environments; the maximum solubility of Taxol in blood is 2.5 × 10¬4 mg/cm³. The viscosity of blood is 0.040 g/cm - s and its density is 1.05 g/cm³. Blood is a complex fluid but you may assume that its average molecular weight is close to that of liquid water. The molecular diffusion coefficient of Taxol in fluid blood is DAB = 1.0 × 10-6 cm²/s.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
Safety Guidelines for Material Handling
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY