3. The loads on a steel beam consist of 150 kN due to dead load and 410 kN due to live load. No other loads need to be considered. Using LRFD, calculate the required strength of the beam. Ans. R = 836 kN 4. The loads on a roof beam consist of a dead load of 2 kN/m, a roof live load of 13 kN/m, and a wind load of 14 kN/m. a. If load and resistance factor design is used, determine the factored load (required strength) to be used in the design of this beam. Which AISC load combination controls? b. If allowable strength design is used, determine the required load capacity (required strength) to be used in the design of the column. Which AISC load combination controls? Ans. a) Ru = 34.4 kN; b) Ra = 22.25 kN

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
Please show complete solutions.
3. The loads on a steel beam consist of 150 kN due to dead load and 410 kN due to live load. No other loads need to be
considered. Using LRFD, calculate the required strength of the beam.
Ans, Ru = 836 kN
4. The loads on a roof beam consist of a dead load of 2 kN/m, a roof live load of 13 kN/m, and a wind load of 14 kN/m.
a. If load and resistance factor design is used, determine the factored load (required strength) to be used in the design
of this beam. Which AISC load combination controls?
b. If allowable strength design is used, determine the required load capacity (required strength) to be used in the
design of the column. Which AISC load combination controls?
Ans. a) Ru = 34.4 kN; b) Ra = 22.25 kN
Transcribed Image Text:3. The loads on a steel beam consist of 150 kN due to dead load and 410 kN due to live load. No other loads need to be considered. Using LRFD, calculate the required strength of the beam. Ans, Ru = 836 kN 4. The loads on a roof beam consist of a dead load of 2 kN/m, a roof live load of 13 kN/m, and a wind load of 14 kN/m. a. If load and resistance factor design is used, determine the factored load (required strength) to be used in the design of this beam. Which AISC load combination controls? b. If allowable strength design is used, determine the required load capacity (required strength) to be used in the design of the column. Which AISC load combination controls? Ans. a) Ru = 34.4 kN; b) Ra = 22.25 kN
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Physical laws and observations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning