3 A three phase power system has two generator connected in parallel to a transformer and subsequently to a 230 kV transmission line. The ratings for the components are given as below: Generator 1:10 MVA, reactance of 12%. Generator 2: 5 MVA, reactance of 8%. Transformer: 15 MVA, reactance of 6% Transmission line: impedance of 4+j60 2, for which the reactances in percentage are based on the ratings of the respective components. Obtain the reactance and impedance values of the components in the custom in naroontogo bocad on 15 MYA and rotad Jtage of the nomponente

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
2.5.3 A three phase power system has two generator connected in parallel to a
transformer and subsequently to a 230 kV transmission line. The ratings for the
components are given as below:
Generator 1:10 MVA, reactance of 12%.
Generator 2: 5 MVA, reactance of 8%.
Transformer: 15 MVA, reactance of 6%
Transmission line: impedance of 4+j60 2,
for which the reactances in percentage are based on the ratings of the respective
components. Obtain the reactance and impedance values of the components in the
system in percentage, based on 15 MVA and rated voltage of the components.
Transcribed Image Text:2.5.3 A three phase power system has two generator connected in parallel to a transformer and subsequently to a 230 kV transmission line. The ratings for the components are given as below: Generator 1:10 MVA, reactance of 12%. Generator 2: 5 MVA, reactance of 8%. Transformer: 15 MVA, reactance of 6% Transmission line: impedance of 4+j60 2, for which the reactances in percentage are based on the ratings of the respective components. Obtain the reactance and impedance values of the components in the system in percentage, based on 15 MVA and rated voltage of the components.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Types of Distribution in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,