2.a. Four electricians are discussing the installation of a luminaire in a clothes closet. Electrician A says that because the clothes-hanging rod is located five inches from the ceiling, the light fixture that's to be mounted directly over the rod must be recessed. Electrician B says that a surface-mounted incandescent fixture must be placed at least six inches from the storage area. Electrician C says that a surface-mounted incandescent fixture must be placed at least 12 inches away from the storage space. Electrician D says that a surfacemounted incandescent fixture must be placed at least nine inches away from the storage space. Which of the following statements is correct? A. Electrician C is correct. B. Electrician A is correct. C. Electrician B is correct. D. Electrician D is correct. 2.b. Four electricians are discussing NEC requirements for common appliances. Electrician A says that new, cord-and-plug, single-phase room A/C units must have factory-installed LCDI or AFCI protection. Electrician B says that the cord for a household refrigerator must be visible and readily accessible to be used as a disconnect switch. Electrician C says that the cord and plug don't have to be new. Electrician D says that an old cord with a spliced new plug can be used. Which of the following statements is correct A. Electrician C is correct. A. Electrician D is correct. B. Electrician A is correct. C. Electrician B is correct. Electrican C not good.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%

2.a. Four electricians are discussing the installation of a luminaire in a clothes closet. Electrician A says that
because the clothes-hanging rod is located five inches from the ceiling, the light fixture that's to be mounted
directly over the rod must be recessed. Electrician B says that a surface-mounted incandescent fixture must
be placed at least six inches from the storage area. Electrician C says that a surface-mounted incandescent
fixture must be placed at least 12 inches away from the storage space. Electrician D says that a surfacemounted incandescent fixture must be placed at least nine inches away from the storage space. Which of
the following statements is correct?
A. Electrician C is correct.
B. Electrician A is correct.
C. Electrician B is correct.
D. Electrician D is correct.

2.b. Four electricians are discussing NEC requirements for common appliances. Electrician A says that new,
cord-and-plug, single-phase room A/C units must have factory-installed LCDI or AFCI protection.
Electrician B says that the cord for a household refrigerator must be visible and readily accessible to be
used as a disconnect switch. Electrician C says that the cord and plug don't have to be new. Electrician D
says that an old cord with a spliced new plug can be used. Which of the following statements is correct A. Electrician C is correct.
A. Electrician D is correct.
B. Electrician A is correct.
C. Electrician B is correct.

Electrican C not good.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Electric heating unit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,