2. Warm water at 45°C is to be cooled to 35°C by counter-current contact with air in a tower packed with wood slats. The inlet air has a dry- bulb temperature of 31°C and a wet-bulb temperature of 22°C. The mass flow rate of water is 5000 kg/m².h and that of air is 1.2 times the minimum. The individual gas-phase mass transfer coefficient is ky'a = 6000 kg/m3.h.AY'. The volumetric water-side heat transfer coefficient is given by h a = 0.059 x L0.51 x Gs, in kcal/m³.h.K, where L and Gs are mass low rates of water and air (dry basis). Determine (a) the dry air flow rate to be used (bne height of packing

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question

Please answer the question correctly providing necessary diagrams charts and graphs 

2. Warm water at 45°C is to be cooled to 35°C by
counter-current contact with air in a tower
packed with wood slats. The inlet air has a dry-
bulb temperature of 31°C and a wet-bulb
temperature of 22°C. The mass flow rate of water
is 5000 kg/m².h and that of air is 1.2 times the
minimum. The individual gas-phase mass
transfer coefficient is ky'a = 6000 kg/m3.h.AY'.
The volumetric water-side heat transfer
coefficient is given by h a = 0.059 x L0.51 x Gs, in
kcal/m³.h.K, where L and Gs are mass low rates
of water and air (dry basis).
Determine
(a) the dry air flow rate to be used
(bne height of packing
Transcribed Image Text:2. Warm water at 45°C is to be cooled to 35°C by counter-current contact with air in a tower packed with wood slats. The inlet air has a dry- bulb temperature of 31°C and a wet-bulb temperature of 22°C. The mass flow rate of water is 5000 kg/m².h and that of air is 1.2 times the minimum. The individual gas-phase mass transfer coefficient is ky'a = 6000 kg/m3.h.AY'. The volumetric water-side heat transfer coefficient is given by h a = 0.059 x L0.51 x Gs, in kcal/m³.h.K, where L and Gs are mass low rates of water and air (dry basis). Determine (a) the dry air flow rate to be used (bne height of packing
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 5 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The