2- for the floor system shown below with assuming that service dead load 3 kN/m?, live load 4 kN/m², Answer the following: 1- Classify the floor system into one way or two-way slab. 2- Check the proposed slab thickness according to deflection and shear requirement. 3- Check the proposed reinforcement at top and bottom in direction shown below. 4- What is the ultimate load transfer from slab and brick wall on beam AB? f = 28MPA , fy = 400MPA and y for brick wall = 17KN/m³ -5.20 m -5.20 m A Ko120250 mm T 6.00m opening 012@200 mm 3.08 m 0.30 m 0.18m section AA

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
icon
Concept explainers
Question
100%
for the floor system shown below with assuming that service dead load 3 kN/m?, live load 4 kN/m², Answer the following: 1- Classify the floor system into one way or two-way slab. 2- Check the proposed slab thickness according to deflection and shear requirement. 3- Check the proposed reinforcement at top and bottom in direction shown below. 4- What is the ultimate load transfer from slab and brick wall on beam AB? f = 28MPa , fy = 400MPA and y for brick wall = 17kN/m
2- for the floor system shown below with assuming that service dead load 3
kN/m?, live load 4 kN/m², Answer the following:
1- Classify the floor system into one way or two-way slab.
2- Check the proposed slab thickness according to deflection and shear
requirement.
3- Check the proposed reinforcement at top and bottom in direction shown
below.
4- What is the ultimate load transfer from slab and brick wall on beam AB?
f = 28MPA, fy = 400MPA and y for brick wall = 17kN/m³
-5.20 m
5.20 m
A
0120250 mm T
6.00m
%3D
opening
012@200 mm 8
3.08 m
0.30 m
0.18m
section AA
Transcribed Image Text:2- for the floor system shown below with assuming that service dead load 3 kN/m?, live load 4 kN/m², Answer the following: 1- Classify the floor system into one way or two-way slab. 2- Check the proposed slab thickness according to deflection and shear requirement. 3- Check the proposed reinforcement at top and bottom in direction shown below. 4- What is the ultimate load transfer from slab and brick wall on beam AB? f = 28MPA, fy = 400MPA and y for brick wall = 17kN/m³ -5.20 m 5.20 m A 0120250 mm T 6.00m %3D opening 012@200 mm 8 3.08 m 0.30 m 0.18m section AA
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Load and resistance factor design
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning