16-5 A two-stage ammonia system using flash-gas removal and intercooling operates on the cycle shown in Fig. 16-1 2a. The condensing temperature is 35°C. The satura- tion temperature of the intermediate-temperature evaporator is 0°C, and its capacity is 150 kW. The saturation temperature of the low-temperature evaporator is -40°C, and its capacity is 250 kW. What is the rate of refrigerant compressed by the high-stage compressor? Ans. 0.411 kg/s

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
Condenser
40°C
High-stage
compressor
Evaporator
S°C
200 kW
Intercooler and
flash tank
Evaporator
-30°C
180 kW
Low-stage
compressor
(a)
40°C
1557 kPa
5°C
517 kPa
2
-30°C
120 kPa
Enthalpy, kJ/kg
(b)
Figure 16-12 (a) Two com pressors and two evaporators operating with intercooling and flash-gas
removal. (b) The pressure-enthalpy diagram corresponding to the system in (a).
Pressure, kPa
Transcribed Image Text:Condenser 40°C High-stage compressor Evaporator S°C 200 kW Intercooler and flash tank Evaporator -30°C 180 kW Low-stage compressor (a) 40°C 1557 kPa 5°C 517 kPa 2 -30°C 120 kPa Enthalpy, kJ/kg (b) Figure 16-12 (a) Two com pressors and two evaporators operating with intercooling and flash-gas removal. (b) The pressure-enthalpy diagram corresponding to the system in (a). Pressure, kPa
16-5 A two-stage ammonia system using flash-gas removal and intercooling operates
on the cycle shown in Fig. 16-12a. The condensing temperature is 35°C. The satura-
tion temperature of the intermediate-temperature evaporator is 0°C, and its capacity is
150 kW. The saturation temperature of the low-temperature evaporator is -40°C, and
its capacity is 250 kW. What is the rate of refrigerant compressed by the high-stage
compressor? Ans. 0.411 kg/s
Transcribed Image Text:16-5 A two-stage ammonia system using flash-gas removal and intercooling operates on the cycle shown in Fig. 16-12a. The condensing temperature is 35°C. The satura- tion temperature of the intermediate-temperature evaporator is 0°C, and its capacity is 150 kW. The saturation temperature of the low-temperature evaporator is -40°C, and its capacity is 250 kW. What is the rate of refrigerant compressed by the high-stage compressor? Ans. 0.411 kg/s
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY