13eku /luv 2p:(1+0 For the following power system, all the impedances are in p.u, except for Zn. Assume pre-fault voltage=1.0 p.u. 3 Lond Line (Sbase X= lo4 20MUA 138kv /buv Zp:(I+jo) A Bas Xu: 30l -- Single-lihe Drayram, a. Draw the sequence networks b. Using the sequence networks, find: i. Pre-fault phase currents (in p.u, with angles). ii. Three-Phase short-circuit phase currents (in p.u. with angles) for a fault at: (Neglect pre-fault currents and assume pre-fault voltage=1.0 p.u.) 1. Bus 2 2. Bus 3 ii. Short-Circuit Capacity (assume VI=1.0 p.u. for each bus) at: 1. Bus 2 2. Bus 3 3. Explain why the SCC of Bus 2 is greater than SCC of bus 3.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question

Please provide Handwritten answer

1- For the following power system, all the impedances are in p.u, except for Zn.
Assume pre-fault voltage=1.0 p.u.
13.8kv
Loud
3
Line
2OMUA
YBase 138ku
O Gen.
2SMV A X,= lou
Zp-(I+jo),
138kv /uv
Xu: 30l
Single-Iihe Decgrann.
.
a. Draw the sequence networks
b. Using the sequence networks, find:
i. Pre-fault phase currents (in p.u, with angles).
ii. Three-Phase short-circuit phase currents (in p.u. with angles) for a fault at:
(Neglect pre-fault currents and assume pre-fault voltage=1.0 p.u.)
1. Bus 2
2. Bus 3
ii. Short-Circuit Capacity (assume VI=1.0 p.u. for each bus) at:
1. Bus 2
2.
Bus 3
3. Explain why the SCC of Bus 2 is greater than sCC of bus 3.
Transcribed Image Text:1- For the following power system, all the impedances are in p.u, except for Zn. Assume pre-fault voltage=1.0 p.u. 13.8kv Loud 3 Line 2OMUA YBase 138ku O Gen. 2SMV A X,= lou Zp-(I+jo), 138kv /uv Xu: 30l Single-Iihe Decgrann. . a. Draw the sequence networks b. Using the sequence networks, find: i. Pre-fault phase currents (in p.u, with angles). ii. Three-Phase short-circuit phase currents (in p.u. with angles) for a fault at: (Neglect pre-fault currents and assume pre-fault voltage=1.0 p.u.) 1. Bus 2 2. Bus 3 ii. Short-Circuit Capacity (assume VI=1.0 p.u. for each bus) at: 1. Bus 2 2. Bus 3 3. Explain why the SCC of Bus 2 is greater than sCC of bus 3.
Expert Solution
steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
8085 Microprocessor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,