12. A 7 kVA, 550/110 V transformer has equivalent resis- Ω. tance refered to primary, Req(HV) = 1.13 2 and equiv- alent reactance referred to primay, Xeq(HV) = 4.71 N. A lagging load is being supplied by it resulting in the following meter readings (meters are placed on the HV side): I₁ == 8.0 A, V₁ = 550 V, P₁ = 3.4 kW For this condition calculate what a voltmeter would read if con- nected across the load terminals. Neglect the no-load current of the transformer.
12. A 7 kVA, 550/110 V transformer has equivalent resis- Ω. tance refered to primary, Req(HV) = 1.13 2 and equiv- alent reactance referred to primay, Xeq(HV) = 4.71 N. A lagging load is being supplied by it resulting in the following meter readings (meters are placed on the HV side): I₁ == 8.0 A, V₁ = 550 V, P₁ = 3.4 kW For this condition calculate what a voltmeter would read if con- nected across the load terminals. Neglect the no-load current of the transformer.
Related questions
Question
Please answer in typing format
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps