10-18. Two oil-fired boilers for a 600 megawatt (MW) power plant produce a sound power level of 139 dB (re: 10-¹2 W) at 4,000 Hz, from the induced draft fans. Determine the sound pressure level 408.0 m downwind on a clear winter night when the wind speed is 4.50 m/s, the temperature is 0.0°C, the relative humidity is 30.0 percent, and the barometric pressure is 101.3 kPa. The height of the boiler is 12 m. The height of the receiver is 1.5 m. The ground surface characteristics are shown in Figure P-10-18.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
10-18. Two oil-fired boilers for a 600 megawatt (MW) power plant produce a
sound power level of 139 dB (re: 10-1¹2 W) at 4,000 Hz, from the induced
draft fans. Determine the sound pressure level 408.0 m downwind on a
clear winter night when the wind speed is 4.50 m/s, the temperature is
0.0°C, the relative humidity is 30.0 percent, and the barometric pressure is
101.3 kPa. The height of the boiler is 12 m. The height of the receiver is
1.5 m. The ground surface characteristics are shown in Figure P-10-18.
Grass
12 m
. Concrete
1.5 m
50 m
408.0 m
FIGURE P-10-18
Ground surface characteristics for Problem 10-18.
Boiler
● Receiver
Answer: SPL at 408.0 m = 50.50 or 50 dB at 4,000 Hz
Transcribed Image Text:10-18. Two oil-fired boilers for a 600 megawatt (MW) power plant produce a sound power level of 139 dB (re: 10-1¹2 W) at 4,000 Hz, from the induced draft fans. Determine the sound pressure level 408.0 m downwind on a clear winter night when the wind speed is 4.50 m/s, the temperature is 0.0°C, the relative humidity is 30.0 percent, and the barometric pressure is 101.3 kPa. The height of the boiler is 12 m. The height of the receiver is 1.5 m. The ground surface characteristics are shown in Figure P-10-18. Grass 12 m . Concrete 1.5 m 50 m 408.0 m FIGURE P-10-18 Ground surface characteristics for Problem 10-18. Boiler ● Receiver Answer: SPL at 408.0 m = 50.50 or 50 dB at 4,000 Hz
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Pressurized pipe flow
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning