1.10. QUESTIONS AND DISCUSSION: 1. A transformer is rated at 440/115 V and volt-ampere at 50HZ. State which of the windings must be made with thicker conductor?

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.28MCQ
icon
Related questions
Question
EXPERIMENT NO.1:
11. ΝΑMΕOΕEXPERIMENT:
Polarity and turn ratio of a single phase transformer.
1.2. OBJECTIVE:
To verification (demonstration) of the transformation ratio (turn ratio) or polarity of a
single phase transformer.
1.10. QUESTIONS AND DISCUSSION:
1. A transformer is rated at 440/115 V and volt-ampere at 50HZ. State which of the windings
must be made with thicker conductor?
2. A transformer is rated at 440/115 V and 1.2KVA at 50HZ. The 115V winding rated of the
transformer is connected to a resistor 115Oresistance. What will be the current flowing
through this resistance?
3. A transformer has its primary winding made of two sections each has 1000 turns and
secondary winding has 500 turns as shown in Figure bellow. If 50 V secondary output is to be
obtained, what must be the voltage applied to the primary winding in the following cases
neglecting saturation and leakage.
Case (1) voltage applied between P, and P, with Pz and P3 joined together.
Case (2) voltage applied between P and P2 with P3 and P4 open and isolated.
Case (3) voltage applied between P, and P, with Pg connected to P, and P, connected to Pa.
Transcribed Image Text:EXPERIMENT NO.1: 11. ΝΑMΕOΕEXPERIMENT: Polarity and turn ratio of a single phase transformer. 1.2. OBJECTIVE: To verification (demonstration) of the transformation ratio (turn ratio) or polarity of a single phase transformer. 1.10. QUESTIONS AND DISCUSSION: 1. A transformer is rated at 440/115 V and volt-ampere at 50HZ. State which of the windings must be made with thicker conductor? 2. A transformer is rated at 440/115 V and 1.2KVA at 50HZ. The 115V winding rated of the transformer is connected to a resistor 115Oresistance. What will be the current flowing through this resistance? 3. A transformer has its primary winding made of two sections each has 1000 turns and secondary winding has 500 turns as shown in Figure bellow. If 50 V secondary output is to be obtained, what must be the voltage applied to the primary winding in the following cases neglecting saturation and leakage. Case (1) voltage applied between P, and P, with Pz and P3 joined together. Case (2) voltage applied between P and P2 with P3 and P4 open and isolated. Case (3) voltage applied between P, and P, with Pg connected to P, and P, connected to Pa.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning