1. A PT100 RTD has a positive temperature coefficient (a) of 0.00392 /°C. It is being used to monitor the temperature in a room. If the present resistance reading of the RTD is 115 02. What is the room temperature? Hint: R = Ro (1+q AT) 2. A differential pressure transmitter's output is a 4-20mA signal. If the input is set to measure liquid level in a tank at 0-15 meters, what is the Liquid level when the transmitter's output is 13mA? 3. An ON-OFF temperature controller controls a room air conditioner. The bandwidth (OH) is set to 4, and

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Please answer number 2
1. A PT100 RTD has a positive temperature coefficient (a) of 0.00392 0/°C. It is being used to monitor the
temperature in a room. If the present resistance reading of the RTD is 115 02. What is the room
temperature? Hint: R = Ro (1+q AT)
2. A differential pressure transmitter's output is a 4-20mA signal. If the input is set to measure liquid level
in a tank at 0-15 meters, what is the Liquid level when the transmitter's output is 13mA?
3. An ON-OFF temperature controller controls a room air conditioner. The bandwidth (OH) is set to 4, and
the desired room temperature, Set Value (SV) is 25°C. At what temperature will the aircon switch ON
and switch OFF?
Transcribed Image Text:1. A PT100 RTD has a positive temperature coefficient (a) of 0.00392 0/°C. It is being used to monitor the temperature in a room. If the present resistance reading of the RTD is 115 02. What is the room temperature? Hint: R = Ro (1+q AT) 2. A differential pressure transmitter's output is a 4-20mA signal. If the input is set to measure liquid level in a tank at 0-15 meters, what is the Liquid level when the transmitter's output is 13mA? 3. An ON-OFF temperature controller controls a room air conditioner. The bandwidth (OH) is set to 4, and the desired room temperature, Set Value (SV) is 25°C. At what temperature will the aircon switch ON and switch OFF?
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,