1. A home has a floor area of 1500 ft2 , the following fixed loads 3000 VA for two small appliance circuits and 1500 VA for 100% laundry. two small appliance circuits and 1500 VA for 100% laundry. The appliances are a 12kw stove and a 5.5kw, 240 V dryer. Assume a factor of 70% for both appliances for the neutral calculation. The ambient temperature is 42 c - Calculate general lighting load - Estimate the number of lighting circuits that will be 20A at 120V. - Estimate the number of circuits there will be at 20A at 120 for small appliances and laundry. and laundry. - Calculate TOTAL EFFECTIVE LOAD (VA)
1. A home has a floor area of 1500 ft2 , the following fixed loads 3000 VA for two small appliance circuits and 1500 VA for 100% laundry. two small appliance circuits and 1500 VA for 100% laundry. The appliances are a 12kw stove and a 5.5kw, 240 V dryer. Assume a factor of 70% for both appliances for the neutral calculation. The ambient temperature is 42 c - Calculate general lighting load - Estimate the number of lighting circuits that will be 20A at 120V. - Estimate the number of circuits there will be at 20A at 120 for small appliances and laundry. and laundry. - Calculate TOTAL EFFECTIVE LOAD (VA)
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.31P: Consider two interconnected voltage sources connected by a line of impedance Z=jX, as shown in...
Related questions
Question
1. A home has a floor area of 1500 ft2 , the following fixed loads 3000 VA for two small appliance circuits and 1500 VA for 100% laundry.
two small appliance circuits and 1500 VA for 100% laundry. The
appliances are a 12kw stove and a 5.5kw, 240 V dryer. Assume
a factor of 70% for both appliances for the neutral calculation.
The ambient temperature is 42 c
- Calculate general lighting load
- Estimate the number of lighting circuits that will be 20A at 120V.
- Estimate the number of circuits there will be at 20A at 120 for small appliances and laundry.
and laundry.
- Calculate TOTAL EFFECTIVE LOAD (VA)
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 2 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning