1) The incremental fuel costs, in dollars per mega watt hour for two units in a plant are given by : = 0,009 P₂ +6 dF P = 0,007 P₁ + 7 and df₂ dP₂ During 24 hour period the load on each unit varies between loo Mw and 500 MW, Whereas the plant output varies from 200 MW to 700 MW. a) At what power level should unit 2 begin to take on all the additional load for the most economic operation of the plant? b) What is the power output of the plant at this point? Neglect Josses. Select one: O a: 222, 22 MW O b: 122, 22 MW OC: 122, 22 MW b: 122, 22 Kw b: 222, 22 MW b: 222, 22 kW b; 122, 22M W

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
1) The incremental fuel costs, in dollars per mega watt hour
for two units in a plant are given by :
dF
dpi
= 0,007 P₁ + 7
and df₂
dP₂
= 0,009²₂ +6
24 hour period the load
each unit varies between
During
loo Mw and 500 MW, Whereas the plant output varies from
200 MW to 700 MW.
a) At what power level should unit 2 begin to take on all
the additional load for the most economic operation of the
plant?
Select one:
O a: 222, 22 MW
O b: 122, 22 MW
OC: 122, 22 MW
Od. 222, 22 MW
b) What is the power output of the plant at this point ?
Neglect losses.
b: 122, 22 Kw
b: 222, 22 MW
b: 222, 22
b: 122, 22M W
on
KW
Transcribed Image Text:1) The incremental fuel costs, in dollars per mega watt hour for two units in a plant are given by : dF dpi = 0,007 P₁ + 7 and df₂ dP₂ = 0,009²₂ +6 24 hour period the load each unit varies between During loo Mw and 500 MW, Whereas the plant output varies from 200 MW to 700 MW. a) At what power level should unit 2 begin to take on all the additional load for the most economic operation of the plant? Select one: O a: 222, 22 MW O b: 122, 22 MW OC: 122, 22 MW Od. 222, 22 MW b) What is the power output of the plant at this point ? Neglect losses. b: 122, 22 Kw b: 222, 22 MW b: 222, 22 b: 122, 22M W on KW
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Types of Power Station and Its Characteristics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,