1) Power for the field devices typically comes from ________. A) The PLC power supply B) Isolated factory floor voltage sources C) The PLC I/O module D) None of the above

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%

1) Power for the field devices typically comes from ________.
A) The PLC power supply B) Isolated factory floor voltage sources
C) The PLC I/O module D) None of the above
1)
2) The output of a TON timer is true when
A) its input (IN) is true and the elapsed time (ET) is less than the preset time (PT)
B) its input (IN) is false and the elapsed time (ET) exceeds the preset time (PT)
C) its input (IN) is false and the elapsed time (ET) is less than the preset time (PT)
D) its input (IN) is true and the elapsed time (ET) exceeds the preset time (PT)
2)
3) Convert 8B3F16 to binary.
A) 1011001111100011 B) 011010
C) 35647 D) 1000101100111111
3)
4) The memory size of a double word (DWord or MD) is ________.
A) Eight bits B) Four bytes C) Sixteen bits D) Eight bytes
4)
5) PLCs are ________ designed for use in the control of a wide variety of manufacturing machines and
systems.
A) personal computers B) electromechanical systems
C) special-purpose industrial computers D) All of the above
5)
6) Convert 11001010001101012 to hexadecimal.
A) 53AC1 B) 121035 C) CA35 D) 530121
6)
7) A TOF timer's output is true only
A) a specified time after its input transitions from false to true
B) when the PLC is not running the program
C) a specified time after its input transitions from true to false
D) after its elapsed time (ET) has exceeded its preset time (PT)
7)
8) In the Siemens PLC environment, which of the indicated data types is used for data 8 bits long?
A) BOOL B) SINT C) DINT D) INT
8)
9) When power is switched from Stop to Run on a Siemens PLC, the CPU initiates a complete restart
by executing
A) OB1 B) OB1000 C) FC1 D) OB100
9)
1
10) Comparison instructions
A) may be used only in OR (parallel) configurations
B) cannot be used with PLC timer instructions
C) may be combined in AND (series) as well as OR (parallel) configurations
D) may be used only in AND (series) configurations
10)

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Analysis of Multiple Order System and Steady State Error
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,