1 In definite distanse ralay the relay operate when the voltage to current ratio falls below the pre- determined value 2 The deflecting torque in distance relay is torque due to voltage coil 3 The incipient fault term in power system fault occurs as a result of an immediate complete breakdown of insulation A TI Lilli C. 10 TF T F TIF

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
Answer with True (T) or False (F) for the following questions:
1
In definite distanse ralay the relay operate when the voltage to current ratio falls below the pre-
determined value
2
3
4
5
6
The deflecting torque in distance relay is torque due to voltage coil
The incipient fault term in power system fault occurs as a result of an immediate complete
breakdown of insulation
The stabilized resistance is used to maintain the stability of differential relay of busbars when
a through fault occurs inside of the protected zone.
One of the advantages of SF6 circuit over the other CBs is that SF6 gas can work for many
times without reconditioning and interput a very huge currents
One of the methods to minimize errors in instrument transformer is by using a rectangular type
core to reduce the number of joints.
7
The reach point of the second step of three-stepped distance protection covering the remaining
20% of the line up to 50% of the next line section
TF
TF
TF
TF
TF
TF
TF
8 Supervisory relay is a sensitive over-voltage relay used with differential relay to detect the
break in the pilot wire from a CT carrying current
9
In definite Time OC Relay the more severe a fault is, the faster it should react to clear it in order TF
to avoid damage to the apparatus
10 In IDMT OC relay, the TMS value when the PSM and relay opetaing time values are 3 and 0.47 TF
sec respectively is 0.02
T F
2
Transcribed Image Text:Answer with True (T) or False (F) for the following questions: 1 In definite distanse ralay the relay operate when the voltage to current ratio falls below the pre- determined value 2 3 4 5 6 The deflecting torque in distance relay is torque due to voltage coil The incipient fault term in power system fault occurs as a result of an immediate complete breakdown of insulation The stabilized resistance is used to maintain the stability of differential relay of busbars when a through fault occurs inside of the protected zone. One of the advantages of SF6 circuit over the other CBs is that SF6 gas can work for many times without reconditioning and interput a very huge currents One of the methods to minimize errors in instrument transformer is by using a rectangular type core to reduce the number of joints. 7 The reach point of the second step of three-stepped distance protection covering the remaining 20% of the line up to 50% of the next line section TF TF TF TF TF TF TF 8 Supervisory relay is a sensitive over-voltage relay used with differential relay to detect the break in the pilot wire from a CT carrying current 9 In definite Time OC Relay the more severe a fault is, the faster it should react to clear it in order TF to avoid damage to the apparatus 10 In IDMT OC relay, the TMS value when the PSM and relay opetaing time values are 3 and 0.47 TF sec respectively is 0.02 T F 2
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Protection System in Power Plant
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,