1- 3-phase 25-kVA 34,5/0,48-kVu distribution transformers are connected in A-Y. Open-circuit test was performed on the low-voltage side of this transformer bank, and the following data were recorded: Vine.OC = 480 V, Iine,OC = 4.10 A, Poc = 945 W Short-circuit test was performed on the high-voltage side of this transformer bank, and the following data were recorded: Vine SC = 808 V, Iune SC =3.11 A, Psc = 912 W (a) Find the voltage regulation of this transformer bank at the rated load and 0.85 power factor leading. (b) Draw a phasor diagram of this transformer at 0.85 power factor leading.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
1- 3-phase 25-kVA 34,5/0,48-kVu distribution transformers are connected in A-Y.
Open-circuit test was performed on the low-voltage side of this transformer bank, and the following data were
recorded: Vine.OC = 480 V, Iine OC = 4.10 A, Poc = 945 W
Short-circuit test was performed on the high-voltage side of this transformer bank, and the following data were
recorded: Vine SC = 808 V, ljine, SC =3.11 A, Psc = 912 W
(a) Find the voltage regulation of this transformer bank at the rated load and 0.85 power factor leading.
(b) Draw a phasor diagram of this transformer at 0.85 power factor leading.
Transcribed Image Text:1- 3-phase 25-kVA 34,5/0,48-kVu distribution transformers are connected in A-Y. Open-circuit test was performed on the low-voltage side of this transformer bank, and the following data were recorded: Vine.OC = 480 V, Iine OC = 4.10 A, Poc = 945 W Short-circuit test was performed on the high-voltage side of this transformer bank, and the following data were recorded: Vine SC = 808 V, ljine, SC =3.11 A, Psc = 912 W (a) Find the voltage regulation of this transformer bank at the rated load and 0.85 power factor leading. (b) Draw a phasor diagram of this transformer at 0.85 power factor leading.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,