0 m³/day. The used trickling filters shall have a diameter c of 2.4 m. (a) Find the number of filters in each stage so t of the first and second stages are not greater than 40mg/ =ctively. (b) Check the hydraulic and organic loading rates doto:

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
Sanitary Engineering
A two-stage trickling filtration system treats sewage at an average flowrate of
36000 m³/day. The used trickling filters shall have a diameter of 25.1m and a
depth of 2.4 m. (a) Find the number of filters in each stage so that the effluent
BOD of the first and second stages are not greater than 40mg/L and 20mg/L,
respectively. (b) Check the hydraulic and organic loading rates of the first and
second stages. Use the following data:
• The BOD of raw sewage is 250mg/l.
• The percent of BOD removal in primary sedimentation unit is 31%.
• The recirculated flowrate of the first stage is54000m³/day.
• The recirculated flowrate of the second stage is 36000m³/day.
The maximum allowed value of hydraulic loading rate is 40 m³
n³/m².day.
• The maximum allowed value of organic loading rate is 2.4 kg BOD/m³.day.
осно
A
Transcribed Image Text:A two-stage trickling filtration system treats sewage at an average flowrate of 36000 m³/day. The used trickling filters shall have a diameter of 25.1m and a depth of 2.4 m. (a) Find the number of filters in each stage so that the effluent BOD of the first and second stages are not greater than 40mg/L and 20mg/L, respectively. (b) Check the hydraulic and organic loading rates of the first and second stages. Use the following data: • The BOD of raw sewage is 250mg/l. • The percent of BOD removal in primary sedimentation unit is 31%. • The recirculated flowrate of the first stage is54000m³/day. • The recirculated flowrate of the second stage is 36000m³/day. The maximum allowed value of hydraulic loading rate is 40 m³ n³/m².day. • The maximum allowed value of organic loading rate is 2.4 kg BOD/m³.day. осно A
Expert Solution
steps

Step by step

Solved in 5 steps with 14 images

Blurred answer
Knowledge Booster
Storm sewers and detention
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning