. A thermocouple is a temperature-measurement device that consists of two dissimilar metal wires joined at one end. An oversimplified diagram follows. Metal 1 ΡOTENTIOMΕΤER V(mV) Metal 2 A voltage generated at the metal junction is read on a potentiometer or millivoltmeter. When certain metals are used, the voltage varies linearly with the temperature at the junction of the two metals: V(mV) = aT(°C) +b An iron-constantan thermocouple (constantan is an alloy of copper and nickel) is calibrated by inserting its junction in boiling water and measuring a voltage V = 5.27 mV, and then inserting the junction in silver chloride at its melting point and measuring V = 24.88 mV. (a) Derive the linearequation for V(mV) in terms of T(°C). Then convert it to an equation for T in terms of V. (b) If the thermocouple is mounted in a chemical reactor and the voltage is observed to go from 10.0 mV to 13.6 mV in 20 s, what is the average value of the rate of change of temperature, dTldt, during the measurement period? (c) State the principal benefits and disadvantages of thermocouples.
. A thermocouple is a temperature-measurement device that consists of two dissimilar metal wires joined at one end. An oversimplified diagram follows. Metal 1 ΡOTENTIOMΕΤER V(mV) Metal 2 A voltage generated at the metal junction is read on a potentiometer or millivoltmeter. When certain metals are used, the voltage varies linearly with the temperature at the junction of the two metals: V(mV) = aT(°C) +b An iron-constantan thermocouple (constantan is an alloy of copper and nickel) is calibrated by inserting its junction in boiling water and measuring a voltage V = 5.27 mV, and then inserting the junction in silver chloride at its melting point and measuring V = 24.88 mV. (a) Derive the linearequation for V(mV) in terms of T(°C). Then convert it to an equation for T in terms of V. (b) If the thermocouple is mounted in a chemical reactor and the voltage is observed to go from 10.0 mV to 13.6 mV in 20 s, what is the average value of the rate of change of temperature, dTldt, during the measurement period? (c) State the principal benefits and disadvantages of thermocouples.
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Question

Transcribed Image Text:. A thermocouple is a temperature-measurement device that consists of two dissimilar metal wires
joined at one end. An oversimplified diagram follows.
Metal 1
ΡOTENTIOMΕΤER
V(mV)
Metal 2
A voltage generated at the metal junction is read on a potentiometer or millivoltmeter. When certain
metals are used, the voltage varies linearly with the temperature at the junction of the two metals:
V(mV) = aT(°C) +b
An iron-constantan thermocouple (constantan is an alloy of copper and nickel) is calibrated by
inserting its junction in boiling water and measuring a voltage V = 5.27 mV, and then inserting the
junction in silver chloride at its melting point and measuring V = 24.88 mV.
(a) Derive the linearequation for V(mV) in terms of T(°C). Then convert it to an equation for T in terms of V.
(b) If the thermocouple is mounted in a chemical reactor and the voltage is observed to go from
10.0 mV to 13.6 mV in 20 s, what is the average value of the rate of change of temperature,
dTldt, during the measurement period?
(c) State the principal benefits and disadvantages of thermocouples.
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps

Recommended textbooks for you

Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education

Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education

Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY

Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning

Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY