SName __________Tyler Hope________________________
Date ____________11/12/23__________________
Lab 9: Dew Point, Humidity and Barometric Pressure
Objective:
Students will be able to measure dew point and relative humidity using appropriate tools and
methodology.
Water vapor is water that exists in the atmosphere in the gaseous state. The amount of water vapor in the
atmosphere can vary greatly from day to day and across geographic areas. Typically, water volume in the air can
vary up to about 4% by volume and it primarily comes from evaporated seawater. Evaporation is a key step in
the water cycle, where water in the liquid state is converted to the gaseous state. As there is an increase in
temperature, the rate of evaporation increases.
Additionally, having a greater surface area of water in an area and higher wind velocity nearby water surfaces
will result in more evaporation.
What is Humidity?
Humidity refers to the amount of water vapor in the atmosphere. At any given temperature, the atmosphere can
only absorb a limited amount of water before it is fully saturated. This is the saturation point. At the specified
temperature within a region, when saturation is reached, additional water vapor will condense into visible
moisture. Refer to the table below to observe the maximum water vapor content in the atmosphere that can exist
by temperature.
Source: Engineering Toolbox
If the air reaches its saturation point, it is said to be saturated. Relative humidity measures the proportion of
water relative to the maximum amount of water that is possible at the saturation point temperature. Therefore, if
the air contains only one quarter of the water needed to be fully saturated, its relative humidity, expressed as a
percent, is 25%.
Temperature change plays a role in measuring this percent. If the temperature in a region increases and the
amount of moisture remains the same, the relative humidity would lower. Conversely, if the temperature in a
region decreases but the moisture content remains the same, the relative humidity percentage would be higher.
ESC100072103708182023FS1
What is Dew Point?
If you watch the weather report on a local news network, you will probably hear the term, “dew point,” when
referring to atmospheric moisture. The dew point is the temperature at which the moisture in the air becomes
totally saturated. When this temperature is reached, any additional water vapor above the maximum moisture
content will condense into a liquid. When the temperature reaches the dew point temperature, fog near the
ground surface or clouds in the atmosphere will form.
The term dew point refers to a measurement of the absolute
humidity of an area. While relative humidity was a
proportion, absolute humidity refers to 100% water vapor in the atmosphere at that specific temperature. If the
dew point in a region is above 65˚F, then it will feel sticky and uncomfortable outside. The higher the dew
point, the more moisture is in the air in that region!
How do we Measure Humidity and Dew Point?
To measure relative humidity, a hygrometer is used. There are multiple types of hygrometers, but we will focus
on one particular type, referred to as a psychrometer (sling psychrometer) which can be used to measure relative
humidity and dew point. This device consists of two thermometers, attached to a device that can be swung in a
circular motion. One of the thermometers is encased with a wick (fabric material) that is dipped in water before
use. The purpose of the bare (dry-bulb) thermometer is to measure the current
local air temperature. The wick-covered one (wet-bulb) measures a temperature
that is lower, due to evaporation of the water from the bulb when swinging it in
a circular motion. The wet-bulb temperature will only equal the dry-bulb
temperature if the air has reached its saturation point (dew point).
The sling psychrometer is used by swinging the device in a circular motion for a
period of time. Then, the two temperatures are recorded and data tables are used
to measure the relative humidity and dew point. If the air contains more
moisture, the wet-bulb value will be higher. Conversely, the air will be drier
(less moist) when the wet-bulb temperature is lower.
Lab Part 1: Measuring Dew Point and Relative Humidity
Materials:
Sling Psychrometer, Distilled Water, Timer, Data Tables (A, B)
Procedure:
1.
Wet the wick on the wet-bulb thermometer. We will be doing one set of data collection tests inside an
air-conditioned room and one outside. You will only wet the wick
one time
per location (indoors and
outdoors).
2.
We will take an average of four recordings – you will swing the psychrometer in 30 second intervals and
record the temperatures of each thermometer after each interval. Please do not re-wet the wick in
between each interval. Fill in the data table below for each recording.
3.
Find the average dry-bulb and wet-bulb temperatures after all data is collected. Subtract the wet-bulb
from the dry-bulb, which will give you the “depression.”
4.
Refer to your charts – Table A and Table B are used to calculate relative humidity and dew point. The
only values you will use for these tables are the dry-bulb temperature and the depression that you
calculated. The left column will be the dry-bulb temperature and the top will be the depression. Find the
point where the two values meet on the table to determine your results.
Note: If you are confused at
this step, carefully review the pre-lab video under the content tab, lab 9.
ESC100072103708182023FS1
5.
Repeat these steps twice – once for indoors measurements and once for outdoors measurements.
Data Collection Tables:
INDOORS MEASUREMENTS
Dry-Bulb Temperature (˚C)
Wet-Bulb Temperature (˚C)
First 30 Seconds
10
12
Second 30 Seconds
16
15
Third 30 Seconds
17
17
Fourth 30 Seconds
16
17
Average Values
14.75
15.25
Calculated Depression: ______0.5__________
Relative Humidity: _________100________
Dew Point: _______14___________
OUTDOORS MEASUREMENTS
Dry-Bulb Temperature (˚C)
Wet-Bulb Temperature (˚C)
First 30 Seconds
18
16
Second 30 Seconds
20
22
Third 30 Seconds
21
23
Fourth 30 Seconds
20
24
Average Values
19.75
21.25
Calculated Depression: ______1.5__________
Relative Humidity: _______82__________
Dew Point: ________17__________
ESC100072103708182023FS1
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
TABLE A: RELATIVE HUMIDITY
TABLE B: DEW POINT
ESC100072103708182023FS1
.
Lab Part 2: Barometric Pressure
Objective:
Students will be able to read a barometer, understand units of barometric pressure and
isobars, and use weather maps to develop a barograph.
The barometer is an instrument used to measure the weight of air that presses
down on us from above. This value is referred to as barometric pressure. The
original barometer was produced in the 1600s by Evangelista Torricelli. A
mercury barometer has a vertical glass tube, closed on one end, sitting in an
open mercury-filled basin. The mercury within the tube adjusts until the
weight of the column is equal to the atmospheric force exerted on the
reservoir. Barometers may also be water-based or consist of vacuum pump oil
as well.
If your region is experiencing a period of cold, dense and heavy air, then the
atmosphere will press on the mercury in the column more, and the barometer measurement is
referred to as “rising.” Conversely, if your region experiences warmer, lighter air, then the
barometer will be described as “falling.” At sea level, the common atmospheric pressure is 29.92
inches of mercury (expressed as Hg). 29.92 inch of Hg (or 760 mm Hg) is “one atmosphere” of
pressure. In aviation and television weather reports, pressure is given in inches of mercury ("Hg),
while meteorologists use millibars (mb)
, the unit of pressure found on weather maps.
ESC100072103708182023FS1
What are Isobars and Pressure Gradients?
Air pressure varies from region to region and temporally (over time). To interpret weather conditions,
meteorologists must consider air pressure in their measurements and predictions. On a weather map, pressure is
displayed using isobars. Isobars are lines on a weather map that connect points of equal pressure.
The spaces in between isobars indicate the amount of change over a distance. If isobars are close together, this
indicates that the pressure changes rapidly over distance. Conversely, if the isobars are spread apart, the change
is much more gradual. The amount of change of pressure over a distance is referred to as a pressure gradient.
Today, you will be drawing isobars using the following charts.
Rules for Drawing Isobars
1. Draw your isobars in a neat and smooth line instead of a jagged line.
2. An isobar should begin and end at an edge of the map, or, alternatively, loop around and close on itself.
3. An isobar should never branch or fork.
4. An isobar cannot touch or cross other lines.
5. Isobars should be drawn at equal intervals. (1000, 996, 992)
6. Each Isobar line should be labeled.
ESC100072103708182023FS1
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
Chart 1:
Complete the 1008 mb isobar by continuing the line. Hint: The 1008 mb isobar must not cross through
areas of lower pressure. For example, a 1008 mb isobar would NOT go between the 1007 and 1006 points.
Chart 2:
Draw the 988 mb isobar. Cross through the 988 mb points and continue the line where appropriate.
ESC100072103708182023FS1
Chart 3:
Follow the rules for drawing isobars to complete the chart below. Start with 1024 mb and draw isobars
every 4 mb.
ESC100072103708182023FS1
For the final part of this lab activity, you will construct a
barogram
using isobars on actual weather maps. Use the
set of weather maps from the Miami Herald for the
Month of March 1993. This has been provided by your
instructor in the content tab (lab 9). Using the weather
maps provided, analyze the barometric pressures for
Miami and New York City for the month of March, 1993.
Instructions:
Use a red pencil to represent Miami and a blue pencil to
represent New York city. Plot the pressure for each day in March on the blank barogram. Complete the graph by
connecting dots across each dataset. Put your name, the date and the class reference number on the graph.
Once you are done, think critically about the changes that occur throughout the graph that you
produced. Write a paragraph explaining what weather changes might have occurred throughout the
month of March in both regions.
I believe a huge snow storm may have passed through over the month of March. A low pressure sat over the
northeastern coast for about 3 days straight. A stationary front over Miami kept the cold front from moving
further north, causing it to stay in place for a bit. THis led to a huge increase in atmospheric pressure over a few
days.
March would also
mean winter is ending soon and spring is beginning, which could be teh cause of the
sudden weather shift.
ESC100072103708182023FS1
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
ESC100072103708182023FS1
ESC100072103708182023FS1