Using the schematic diagram in Figure 20–23, determine the number of control wires needed to control the three-phase motor. Use the terminal and wire identification shown in the schematic as well as proper power circuit identification.
FIG. 20–23
Calculate the number of control wires required to control the three-phase motor in Figure 20–23.
Explanation of Solution
The 3 wires are connected to the externally operated disconnect switch, and the switch is connected to pull box through 3 wires. Four wires are used to connect stations 1 and 2. Four wires and three wires are used to connect station 2 and station 3 to pull box, respectively. The pull box is connected to motor starter using 6 wires, and finally, starter is connected to a three-phase motor using 3 wires. Redraw the given figure with the representation of the required control wires as shown in Figure 1.
Conclusion:
Thus, the number of control wires required to control the three-phase motor in Figure 20-23 is calculated.
Want to see more full solutions like this?
Chapter 20 Solutions
Electric Motor Control
- 5. A 15-HP motor operates at full-load from a 600 V, 3-phase, 60 Hz, delta connected source. The motor is 75% efficient and its power factor is 0.82 lagging. a. Calculate the line and phase currents b. Draw the circuit identifying one line voltage and line current. Also identify one phase voltage and one phase current on the source. C. What is the power generated by one phase of the delta connected source?arrow_forwardis used to In gas power plant, compress the air and same applied to combustion chamber. O a. Compressor O b. Combustion chamber O c. Turbine d. Condenserarrow_forwarda long shunt compound generator supplies 100A at a terminal voltage of 250V. the resistance of the armature, shunt field and series field are respectively 0.02,50 and 0.05 ohms. The bhp of the driving engine is 38. Calculate the total copper losses.arrow_forward
- b) Figure Q2(b) shows a name plate details of de separately excited motor used in industrial drive. You are required to recommend and justify the suitable converter for controlling the speed of the de motor. Show your answer using suitable illustration and use three phase, 415 V, 50 Hz, ac supply for converter input. ABB Motor Sep. 06-1995 IEC 34-1-1969 Type DMP 112-4L No 1124 01659 12.5 kW 1500 rimin Duty S1 Ins. Class Armature Volt. 300 V Arm. 29.9 A Field Volt. 220 V Exc. 2.18 A IP 23S IC 06 IM 1001 Cat. No. FR 159 101-1A 123.5 kg MADE IN FRANCE FABRIQUE EN FRANCE Figure Q2 (b)arrow_forwardYazı Tipi Paragraf Stiller Düzenleme Ses Duyarlılik 8. 6. 10 I 11 12 13 14 1 15 2 3. 4 Question 1: Explain the dynamo voltage drops as the dynamo is loaded? Question 2: Why does the dynamo speed decrease as the load increases, explain why the asynchronous motor current that rotates the dynamo increases? M ww Question 3: What is the load operating and external characteristic curve of the D.C shunt dynamo with the values obtained from the experiment? Question 4: Considering the dynamo cycle, find the voltage drops due to armature resistance with the values obtained and analyze the result? Question 5: Explain the characteristics of the D.C shunt dynamo and where it is used? D. Odak W REDMI NOTE 9 AI QUAD CAMERAarrow_forwardWhat should be done for the altemator to take active power (load) on synchronous alternators? Devir sayısı artırılır A) The speed (rpm) should be increased Gerilimi arttırılır B) The voltage sould be increased Devir sayısı azaltılır The speed (rpm) shoul be reduced Frekansı azaltılır D) The frequency should be reduced Gerilimi azaltılır E) The voltage should be reducedarrow_forward
- A 3-phase motor is connected to a voltage of 400 V and has a power of 50 kW at full load. When the engine is running at full load, it is delta connected, while at start-up it is star connected. a) Calculate the phase voltage and phase current when running at full load. b) Calculate the phase voltage and phase current at start-up. c) We suspect that one of the supply lines to the motor has been broken. Draw the form for the break in both the delta and star cases. ..arrow_forwardThe pressure gage shown below is used to monitor engine pressure which varies sinusoidally at a frequency of 57.5 [Hz]. Using this setup, answer the following questions. Pressure Transducer DAQ 3450 (RPM) Pressure to voltage Al1+ Vout Ouput arout Al1- Bonding type semicanducter vansducer Startess diaghragm.arrow_forwardThe table gives data for open circuit and short circuit tests on a 6 pole, 440 V, 50 Hz, 3 phase star connected alternator. The effective ohmic resistance between any two terminals of the armature is 0.3 ohm. Field current (A) 24678 10 12 14 OC Vitage (V) 156 288 396 440 474 530 568 592 S.C current 11 22 34 40 46 57 69 80 Find the regulation at full load current of 40 A at 0.8 power factor lagging, using emf method and mmf method.arrow_forward
- Q2. Suggest a suitable method to raise the speed of a de shunt motor 1 Add filearrow_forwardAn electromechanical open-loop control system is shown in the figure below. The generator, driven at a constant speed, provides the field voltage for the motor. The motor has an inertia Jm and bearing friction bm. Obtain the transfer function e The generator voltage vg can be vf(s) assumed to be proportional to the field current iş.arrow_forward1- The below given nameplate a) How can it be run in a network of 50 Hz? b) Will there be any changes in the number of revolutions? Explain in detail? CHICAGO Electric Power Tools INDUSTRIAL МОTOR - 1 НР MODEL: 92105 VOLT: 120 AMPS: 5.5 POLES: 4 HP: 1/2 HZ: 60 RPM: 1725 PHASE: DATE: Oct 18,07 SERIAL#: 070043 MADE IN THAILANDarrow_forward