Chapter 17, Problem 1R

What is the total current draw when all six fluorescent luminaires are turned on?

Expert Solution & Answer
Check Mark
To determine

Find the total current drawn when all the six fluorescent luminaires are turned on.

Answer to Problem 1R

The total current (I) that is drawn when all the six fluorescent luminaires are turned on is 9.2A.

Explanation of Solution

Discussion:

The recreation room consists of six lay in fluorescent luminaires. One fluorescent luminaire consists of four 32W lamp.

No.of watts for one luminaire=4×32W=128W

No.of watts for six luminaire=6×128W=768W

Generally, the power factor of fluorescent luminaire lies between 0.5and0.9. Let us assume the power factor (cosϕ) as 0.762.

No.of VA for six luminaire=No.of watts for six luminairecosϕ

Substitute 768W for No.of watts for six luminaire and 0.762 for cosϕ in the above equation to find No.of VA for six luminaire.

No.of VA for six luminaire=768W0.762=1008VA{1W=1V1A}

The current drawn by the six fluorescent luminaires is calculated as follows:

I=VAfor six luminairessingle phase voltage (1)

Substitute 1008VA for VAfor six luminaires and 120V for single phase voltage in equation (1) to find I.

I=1008VA120V=8.4A

One fluorescent luminaire is controlled by the 3-way switch. It also controls the stairway luminaire of 100W.

When the staircase luminaire is turned on, the value of VA becomes as follows:

Total VA for six luminaires=1008VA+100W=1008VA+100VA{1W=1V1A}=1108VA

Substitute 1008VA for Total VA for six luminaires, and 120V for single phase voltage to find I.

I=1108VA120V=9.2A

Conclusion:

Thus, the total current (I) that is drawn when all the six fluorescent luminaires are turned on is 9.2A.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
Please write all the formulas clearly for each case first, then solve the question by hand on paper and send a clear photo of the solution. Thanks a lot 6 A three-phase transistor voltage-source inverter supplies a three-phase load, as shown in Fig.8.41. The load consists of star connected resistance of 10 in each phase. The inverter supply voltage is 200V d.c. and each inverter switch conducts for 120°. (a) Sketch the switching signals for the six transistors. (b) Sketch the line-to-neutral voltage for one complete cycle of the output voltage. (c) Sketch the line-to-line voltage for one complete cycle of the output voltage. (d) Calculate the rms values of the first five harmonics in the line- to-line output voltage, including the fundamental. (e) Calculate the rms values of the first five harmonics in the line- to-neutral output voltage, including the fundamental. [Ans: (d) VL-L=244.95 V, (e) Vph = 141.42 V] Q1 Q3 Q5 Vdc 200V b Q4 Q6 Q2 Fig.8.41. 120° conuction ww 102 w 1052 ww n 1052
Please write all the Formulas clearly for each case first, then solve the question by hand on paper and send a clear photo of the solution. Thanks a lot Tent waveforms if the Q4) A three-phase inverter supplies a 3-phase load, as shown in Fig (2). The load consists of star connected resistance of 1002 in each phase. The inverter supply voltage is 200 V dc, and each inverter switch conducts 180°. (a) Sketch the switching signals for the six transistors. (b) Sketch the line-line voltage for one complete cycle of the output voltage (c) Sketch the line-line voltage for one complete cycle of the output voltage (d) Calculate the rms values of the first five harmonics in the line-line output voltage, including the fundamental. (e) Calculate the rms values of the first five harmonics in the line-neutral output voltage. including the fundamental.) Vac 200V Q1 Q3 Q5 B Q6 b Q2 ww 10Ω Fig2 3 1092 ww 1092
Please write all the formulas clearly for each case first, then solve the question by hand on paper and send a clear photo of the solution. Thanks a lot A three-phase bridge-inverter is fed from a d.c. source of 200 V. If the load is star-connected of 10 02/phase pure resistance, determine the RMS load current, the required RMS current rating of the thyristors and the load power for (i) 120° firing, and (ii) 180° firing. [Ans (i) 120° firing IL (rms) = 8.16 A, IT(rms) = 9.8 A. Load power = 2000 W. (ii) 180° firing IL (rms) = 9.43 A, IT (rms) = 6.67 A. Load power = 2667 W.]

Additional Engineering Textbook Solutions

Find more solutions based on key concepts
Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Text book image
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Text book image
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Text book image
Electric Motor Control
Electrical Engineering
ISBN:9781133702818
Author:Herman
Publisher:CENGAGE L
Text book image
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Text book image
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License