Design the exterior rectangular column with the given loads. Determine the appropriate dimension in the short direction. Find the required number of 32-mm longitudinal reinforcement bars. Specify the required spacing of 10-mm ties in mm.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
100%

Pls answer.

Subject RCD

Design of short Columns

OBJECTIVE:
Design the exterior rectangular column with the given loads. Determine the appropriate dimension in the
short direction. Find the required number of 32-mm longitudinal reinforcement bars. Specify the required
spacing of 10-mm ties in mm.
Transcribed Image Text:OBJECTIVE: Design the exterior rectangular column with the given loads. Determine the appropriate dimension in the short direction. Find the required number of 32-mm longitudinal reinforcement bars. Specify the required spacing of 10-mm ties in mm.
SITUATION:
The two-story building is analyzed against the gravity loads as shown in the figure below and it is determined
that the exterior column has the following loading:
Pdead = 987 kN
Plive = 1481 kN
Mdead = 220 kN - m
Mlive = 315 kN - m
The maximum dimension allowed due to architectural considerations is 625mm. Concrete strength is 28 MPa
and reinforcement yield strength is 420 MPa. Bending is about the strong axis.
W Live
Column Center Line
PLive
PDead
MDead
MLive
W Dead
W Live
W Dead
The Column
to be Design
Transcribed Image Text:SITUATION: The two-story building is analyzed against the gravity loads as shown in the figure below and it is determined that the exterior column has the following loading: Pdead = 987 kN Plive = 1481 kN Mdead = 220 kN - m Mlive = 315 kN - m The maximum dimension allowed due to architectural considerations is 625mm. Concrete strength is 28 MPa and reinforcement yield strength is 420 MPa. Bending is about the strong axis. W Live Column Center Line PLive PDead MDead MLive W Dead W Live W Dead The Column to be Design
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Follow-up Questions
Read through expert solutions to related follow-up questions below.
Follow-up Question

The required number of diameter bar is 32mm, why you use 36? and can you pls add show drawing or illustration. 
Thank you .

Solution
Bartleby Expert
SEE SOLUTION
Knowledge Booster
Compression members
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning