Building in Nassiriah city is air conditioned with the following assumptions: Sensible heat load 46.4 kW, latent heat load 11.6 kW, outside design conditions 38 C DBT and 28 C WBT, Inside design conditions 24 C DBT and 60 % relative humidity, Infiltrated air 1200 m³/h, Apparatus dew point temperature 10 C, amount of recirculated air from the building 60%, Total mass of air entering the building 975 kg/min, The recirculated air is mixed with the conditioned air after the cooling coil. Find the following: 1-The conditions of air leaving the conditioner coil before mixing with the recirculated air. 2-The conditions of air before entering the building. 3-The mass of air entering the conditioner.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
Q3:
Building in Nassiriah city is air conditioned with the following assumptions:
Sensible heat load 46.4 kW, latent heat load 11.6 kW, outside design conditions 38 C DBT
and 28 C WBT, Inside design conditions 24 C DBT and 60 % relative humidity,
Infiltrated air 1200 m²h, Apparatus dew point temperature 10 C, amount of recirculated
air from the building 60%, Total mass of air entering the building 975 kg/min,
The recirculated air is mixed with the conditioned air after the cooling coil. Find the
following:
1-The conditions of air leaving the conditioner coil before mixing with the recirculated air.
2-The conditions of air before entering the building.
3-The mass of air entering the conditioner.
4-The by-pass factor of the cooling coil.
5-The capacity of cooling coil in Ton of refrigeration.
Transcribed Image Text:Q3: Building in Nassiriah city is air conditioned with the following assumptions: Sensible heat load 46.4 kW, latent heat load 11.6 kW, outside design conditions 38 C DBT and 28 C WBT, Inside design conditions 24 C DBT and 60 % relative humidity, Infiltrated air 1200 m²h, Apparatus dew point temperature 10 C, amount of recirculated air from the building 60%, Total mass of air entering the building 975 kg/min, The recirculated air is mixed with the conditioned air after the cooling coil. Find the following: 1-The conditions of air leaving the conditioner coil before mixing with the recirculated air. 2-The conditions of air before entering the building. 3-The mass of air entering the conditioner. 4-The by-pass factor of the cooling coil. 5-The capacity of cooling coil in Ton of refrigeration.
Expert Solution
steps

Step by step

Solved in 7 steps with 6 images

Blurred answer
Knowledge Booster
Distillation
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The